Catalog No.
KAV02802
Description
PRINCIPLE OF THE ASSAY This assay employs the quantitative indirect enzyme immunoassay technique. Recombinant HRSV F/Fusion glycoprotein F0 has been pre-coated onto a microplate. Standards or samples are pipetted into the wells and any Anti-HRSV F/Fusion glycoprotein F0 Human IgG present is bound by the immobilized protein. After washing away any unbound substances, a biotin-labeled Mouse Anti-Human IgG antibody is added to the wells. After washing away any unbound substances, Streptavidin-HRP is added to the wells. Following a wash to remove any unbound enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of Anti-HRSV F/Fusion glycoprotein F0 Human IgG bound in the initial step. The color development is stopped and the intensity of the color is measured.
Target
F, Fusion glycoprotein F0
Applications
Used for the quantitative determination of Anti-HRSV F/Fusion glycoprotein F0 Human IgG concentration in serum and plasma.
Detection method
Colorimetric
Sample type
Plasma, Serum
Assay type
Quantitative
Range
1.56 ng/mL - 100 ng/mL
Sensitivity
0.88 ng/mL
Precision
Intra-Assay Precision (Precision within an assay): <10%
Three samples of known concentration were tested sixteen times on one plate to assess intra-assay precision.
Inter-Assay Precision (Precision between assays): <15%
Three samples of known concentration were tested in twenty four separate assays to assess inter-assay precision.
Recovery
80-120%
Shipping
2-8 ℃
Stability and Storage
When the kit was stored at the recommended temperature for 6 months, the signal intensity decreased by less than 20%. For unopened kits, if you want to prolong the storage time, please store the Standard, Detection A, Detection B and Microplate at - 20℃, the rest reagents should be store at 4℃.