Applications: Used for the quantitative determination of Anti-MPXV E8L Human IgG concentration in serum and plasma.
Sample type: Plasma, Serum
Sensitivity: 0.31 - 20 ng/mL
Range: 0.30 ng/mL
Overview

Catalog No.

KAV13202

Description

PRINCIPLE OF THE ASSAY This assay employs the quantitative indirect enzyme immunoassay technique. Recombinant MPXV E8L antigen has been pre-coated onto a microplate. Standards or samples are pipetted into the wells and any Anti-MPXV E8L Human IgG present is bound by the immobilized protein. After washing away any unbound substances, a biotin-labeled Mouse Anti-Human IgG antibody is added to the wells. After washing away any unbound substances, Streptavidin-HRP is added to the wells. Following a wash to remove any unbound enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of Anti-MPXV E8L Human IgG bound in the initial step. The color development is stopped and the intensity of the color is measured.

Target

E8L

Applications

Used for the quantitative determination of Anti-MPXV E8L Human IgG concentration in serum and plasma.

Detection method

Colorimetric

Sample type

Plasma, Serum

Assay type

Quantitative

Range

0.30 ng/mL

Sensitivity

0.31 - 20 ng/mL

Precision

Intra-Assay Precision (Precision within an assay): <10%

Three samples of known concentration were tested sixteen times on one plate to assess intra-assay precision.

Inter-Assay Precision (Precision between assays): <15%

Three samples of known concentration were tested in twenty four separate assays to assess inter-assay precision.

 

Intra-Assay Precision

Inter-Assay Precision

Sample

1

2

3

1

2

3

n

16

16

16

24

24

24

Mean (ng/mL)

9.9

2.4

1.2

9.7

2.4

1.1

Standard deviation

0.3

0.1

0.1

0.3

0.1

0.1

CV (%)

2.7

3.7

6.7

2.8

3.4

7.1

Recovery

80-120%

Shipping

2-8 ℃

Stability and Storage

When the kit was stored at the recommended temperature for 6 months, the signal intensity decreased by less than 20%.

Data Image
References
Datasheet
$ 1128
Product specifications
96 T 1128

Contact Information

Order: order@antibodysystem.com

Mail: support@antibodysystem.com

Distributor list

For research use only. Not for human or drug use.

Need help with your order?

Find out more about placing an order here

Anti-MPXV E8L Human IgG ELISA Kit [KAV13202]
Terms of sale Website terms of use Cookie policy Privacy
Copyright © 2025 AntibodySystem SAS. All Rights Reserved.            All Products are for Research Use Only